**United States Sales and Usage Limitation: For Research Use Only. Not for use in diagnostic procedures.
INTENDED USE The Biotrin Human Herpesvirus-6 IgM IFA is intended for the qualitative and semi-quantitative detection of anti-Human Herpesvirus-6 (HHV-6) IgM antibodies in serum and plasma.
ASSAY PRINCIPLE The Biotrin HHV-6 IFA system utilises the indirect immunofluorescent method of antibody detection and titre determination.
Patient samples are incubated with HHV-6 antigen, which has been stabilised on a glass slide. If HHV-6 IgM antibodies are present in the sample, a stable complex is formed between the antibody and the antigen on the slide.
Bound HHV 6 IgM antibody is then reacted with a fluorescein conjugated goat anti-human IgG and this complex is visualised with the aid of a fluorescence microscope.
Positive reactions are denoted by bright green fluorescence of infected cells. Uninfected cells are stained red due to the used of a counter stains Rapid easy to use assay
High levels of cells in each well
Good representation of HHV-6 positive and negative cells in each well
Positive and Negative controls included
Additional Information Frequently asked questions about HHV6 Download Product Instructions for Use (RUO) ORDERING INFORMATION Product Description | Format | Catalogue No. | Human Herpes virus 6 IgM Immunoflurescent Assay** | 4 x 10 well Slides | V17HHV6 | |